Industrial Standards & Hygiene Needs
A certified medical logistics facility required ultra-flat, hygienic, and non-porous floor surfacing capable of withstanding heavy automated guided vehicle (AGV) traffic and frequent chemical disinfection.
Surface Engineering Protocol
- Substrate Preparation: Enclosed dustless shot-blasting to achieve CSP-3 surface profile; moisture barrier epoxy primer applied.
- Body Screed: 3.0mm solvent-free, self-leveling epoxy resin pigmented in industrial grey (RAL 7035).
- Coving & Perimeters: Integrated 100mm seamless radius wall coves to eliminate dirt traps.
- Finish: Aliphatic polyurethane UV-resistant satin topcoat providing Shore D hardness 82.
Project Handover
Delivered on schedule within 8 days with zero downtime for adjacent cold-chain operational corridors.